Computational
Domain

The figure above shows
the proposed computational domain which takes into account the distance of the
riser to the free-surface and to the bottom of the basin. The diameter of the riser without strakes is D=0.2m and the length
L=3.523m. For a reference frame with the origin at the axis of the cylinder in
the mid-section of the riser

a must be larger or equal
than 5 (
). Participants may choose to extend the domain in the longitudinal direction.
It is recommended that participants check the sensitivity of the solution to
the value of a.